Design EN 837-1
Nominal size in mm 160
Accuracy class 0.6
Scale ranges 0 ... 0.6 to 0 ... 600 bar or all other equivalent vacuum or combined pressure and vacuum ranges
Adjustment medium ≤ 25 bar: Gas > 25 bar: Liquid
|
Pressure limitation Steady: Full scale value Fluctuating: 0.9 x full scale value Short time: 1.3 x full scale value
Permissible temperature Ambient: -40 … +60 °C Medium: +80 °C maximum
Temperature effect When the temperature of the measuring system deviates from the reference temperature (+20 °C): max. ±0.4 %/10 K of full scale value
Ingress protection IP 54 per EN 60529 / lEC 529
|