Design EN 837-1
Nominal size in mm 50
Accuracy class 2.5
Scale ranges 0 ... 1.6 to 0 ... 400 bar or all other equivalent vacuum or combined pressure and vacuum ranges
Pressure limitation Steady: 3/4 x full scale value Fluctuating: 2/3 x full scale value Short time: Full scale value
|
Permissible temperature Ambient: -20 … +60 °C Medium: +60 °C maximum
Temperature effect When the temperature of the measuring system deviates from the reference temperature (+20 °C): max. ±0.4 %/10 K of the span
Process connection Cu-alloy, Lower mount (LM) or centre back mount (CBM) G 1/4 B (male), 14 mm flats
Pressure element Cu-alloy, C-type
Movement Cu-alloy
Dial Plastic, white, black lettering