Design EN 837-1
Nominal size in mm 50
Accuracy class 2.5
Indication range 0 ... 400 bar
Pressure limitation Steady: 3/4 x full scale value Fluctuating: 2/3 x full scale value Short time: Full scale value
Permissible temperature At the vehicle: -40 ... +80 °C (permissible temperature range) In the engine compartment: -40 ... +120 °C (for a maximum of 8 hours, at a maximum working pressure of 240 bar)
|
Temperature effect When the temperature of the measuring system deviates from the reference temperature (+20 °C): max. ±0.4 %/10 K of the span
Process connection Cu-alloy, lower mount (LM) G 1/4 B (male), 14 mm flats
Pressure element Cu-alloy, helical type
Movement Cu-alloy
Dial Plastic, white, with pointer stop pin
Pointer Plastic, black, special design
|