Industrial RTD Assembly Type TR10
|
Applications
- Air conditioning and refrigeration systems
- Chemical and petrochemical industries
- Electronics and semiconductor industries
- Energy and power plant technology
- Machinery, plant and tank measurement
- Oil and gas industries
- Offshore exploration and drilling
- Pipeline control and custody transfer
- Power and utilities
- Pulp and paper
- Water and wastewater treatment
Special Features
- The sensor can be mounted into a thermowell or directly into a process with the use of a fixed, spring loaded or compression process fitting.
- The assembly can be supplied with or without a transmitter. Transmitters convert the resistance signal from the RTD to a linear analog or digital output (commonly 4-20 mA). This signal reduces potential inaccuracies by negating the need for compensating output lead wires.
- The assembly has electrical approvals for explosion proof hazardous locations, intrinsic safety, ingress protection and general purpose areas.
- The RTD sensors available for this assembly consist of a variety of sheath materials including stainless steels, corrosion resistant and high temperature oxidation resistant alloys. For temperatures greater than 1112°F, it is advisable to utilize an Inconel 600 sheath in place of stainless steel.
- RTD diameters range from 0.125 inch to 0.250 inch and 2 mm to 8 mm. Standard diameters are 0.125 inch & 0.250 inch and 3 mm & 6 mm.
|
Industrial RTD Assembly Type TR10
|
|
Specifications
|
|
| Sensor Element: |
|
Pt100, Pt1000, Pt10, Cu10, or Ni120
|
| |
|
|
| Measuring range: |
|
-328°F to +1832°F (depending upon element) |
| |
|
|
| Wiring configuration: |
|
2, 3, and 4 wire (single or dual) |
| |
|
|
| Classification tolerance: |
|
Class B to DIN EN 60751 |
| |
|
Class A to DIN EN 60751 |
| |
|
1/3 of DIN Class B |
| |
|
1/10 of DIN Class B |
| |
|
Less than class B |
| |
|
|
| Electrical approvals: |
|
CSA, FM, ATEX/IEC, NAMUR |
| |
|
|
| Options: |
|
Lengths and diameters standard or customer specific |
| |
|
Transmitter mounted directly within connection head or on measuring insert DIN plate |
| |
|
Calibration – single point, multiple points,and to Callendar-Van Dusen coefficients |
| |
|
Material traceability of the conductors, metal sheath and mineral insulation |
| |
|
Selectable accuracy Tolerance |
| |
|
Exchangeable measuring insert |
| |
|
Special designs and materials |
| |
|
Explosion protection: CSA, FM, ATEX (EEx-d) |
| |
|
Intrinsically safe version: ATEX (EEx-i) |
| |
|
Non-sparking version: ATEX (EEx-n) |
| |
|
RTD transmitter matching |
|
| |