Industrial RTD Assembly
Type TR10


Applications

  • Air conditioning and refrigeration systems
  • Chemical and petrochemical industries
  • Electronics and semiconductor industries
  • Energy and power plant technology
  • Machinery, plant and tank measurement
  • Oil and gas industries
  • Offshore exploration and drilling
  • Pipeline control and custody transfer
  • Power and utilities
  • Pulp and paper
  • Water and wastewater treatment

Special Features

  • The sensor can be mounted into a thermowell or directly into a process with the use of a fixed, spring loaded or compression process fitting.
  • The assembly can be supplied with or without a transmitter. Transmitters convert the resistance signal from the RTD to a linear analog or digital output (commonly 4-20 mA). This signal reduces potential inaccuracies by negating the need for compensating output lead wires.
  • The assembly has electrical approvals for explosion proof hazardous locations, intrinsic safety, ingress protection and general purpose areas.
  • The RTD sensors available for this assembly consist of a variety of sheath materials including stainless steels, corrosion resistant and high temperature oxidation resistant alloys. For temperatures greater than 1112°F, it is advisable to utilize an Inconel 600 sheath in place of stainless steel.
  • RTD diameters range from 0.125 inch to 0.250 inch and 2 mm to 8 mm. Standard diameters are 0.125 inch & 0.250 inch and 3 mm & 6 mm.


Industrial RTD Assembly Type TR10

Specifications

 
Sensor Element:  

Pt100, Pt1000, Pt10, Cu10, or Ni120

     
Measuring range:   -328°F to +1832°F (depending upon element)
     
Wiring configuration:   2, 3, and 4 wire (single or dual)
     
Classification tolerance:   Class B to DIN EN 60751
    Class A to DIN EN 60751
    1/3 of DIN Class B
    1/10 of DIN Class B
    Less than class B
     
Electrical approvals:   CSA, FM, ATEX/IEC, NAMUR
     
Options:   Lengths and diameters standard or customer specific
    Transmitter mounted directly within connection head or on measuring insert DIN plate  
    Calibration – single point, multiple points,and to Callendar-Van Dusen coefficients  
    Material traceability of the conductors, metal sheath and mineral insulation
    Selectable accuracy Tolerance
    Exchangeable measuring insert
    Special designs and materials
    Explosion protection: CSA, FM, ATEX (EEx-d)
    Intrinsically safe version: ATEX (EEx-i)
    Non-sparking version: ATEX (EEx-n)
    RTD transmitter matching
© 2013 - WIKA Instruments Limited